Empresa de carbón activado Huamei

Activated Carbon for Gas Treatment: Mercury, H₂S, VOC & More

octubre 7, 2026

Activated carbon is used in natural gas processing at multiple stages — from wellhead gas cleanup to pipeline-quality polishing. Each stage targets different contaminants and requires different carbon specifications.

This guide covers the main gas treatment applications, the carbon types and specs for each, and how to specify carbon for your gas processing project.

What Activated Carbon Removes from Gas Streams

Industrial gas treatment with activated carbon targets these contaminant groups:

Contaminant Sources Why It Must Be Removed Carbon's Role
H₂S Natural gas,

biogas, syngas

Toxic, corrosive,

poisons catalysts

Catalytic oxidation

(impregnated carbon)

or adsorption

Mercaptans

(R-SH)

Natural gas, LPG Odor, corrosion Physical adsorption +

catalytic oxidation

Mercury

(Hg⁰)

Natural gas

(0.01–5,000 µg/Nm³)

Poisons aluminum

heat exchangers in LNG

plants,

environmental hazard

Chemisorption on

sulfur-impregnated

carbon

BTEX Natural gas,

associated gas

Contaminates glycol,

causes emissions

Physical adsorption

in micropores

Siloxanes Biogas,

landfill gas

Forms abrasive SiO₂

deposits in engines

Physical adsorption
COV Process vents,

tank emissions,

fugitive sources

Emissions compliance,

health hazard

Adsorption with optional

thermal desorption

Natural Gas Processing Applications

1. Mercury Removal for LNG Production

Mercury in natural gas, even at trace levels (µg/Nm³), destroys the aluminum brazed heat exchangers used in LNG cryogenic processing. A single mercury excursion can cause liquid metal embrittlement that costs millions in repairs and months of downtime.

Sulfur-impregnated activated carbon is the standard mercury guard in LNG feed gas treatment. The sulfur reacts with elemental mercury to form mercuric sulfide (HgS), a stable and non-volatile compound trapped permanently in the carbon pores.

Especificaciones:

  • Carbon type: coal-based pellet (3–4 mm) or granular (4×10 mesh)
  • Impregnation: elemental sulfur, 10–15% by weight
  • Mercury capacity: 10–20% of carbon weight (theoretical); practical capacity depends on inlet concentration and contact time
  • Operating temperature: 20–60°C
  • EBCT: 5–15 seconds for guard beds
  • Outlet target: <0.01 µg/Nm³ mercury

Mercury removal beds are non-regenerable — the carbon is replaced when capacity is exhausted. Bed life ranges from 3–10 years depending on inlet mercury levels.

2. H₂S and Mercaptan Removal

For natural gas with H₂S levels below 1,000 ppm, impregnated activated carbon provides a simpler alternative to amine systems. This is common for small-to-medium gas fields, marginal wells, and gas gathering stations where installing an amine plant isn't economical.

For a comprehensive guide to H₂S removal with activated carbon — including biogas, natural gas, and refinery applications — see our detailed article on activated carbon for sulfur removal.

Key specs for gas sweetening:

  • Carbon type: coal-based pellet, 3–4 mm
  • Impregnation: KOH (5–10%) for H₂S; virgin carbon or NaOH-impregnated for mercaptans
  • H₂S capacity: 0.15–0.25 g/g (KOH) or 0.20–0.40 g/g (KI)
  • Pressure: systems must be rated for pipeline operating pressure

3. BTEX Removal from Glycol Dehydration

Triethylene glycol (TEG) dehydration systems absorb BTEX along with water from natural gas. When the glycol is regenerated, BTEX is released — creating an emission source that may require control under environmental regulations.

An activated carbon bed on the glycol regeneration vent captures BTEX before it enters the atmosphere. The carbon can be thermally regenerated or replaced periodically.

Especificaciones:

  • Carbon type: coal-based granular, 4×10 or 8×30 mesh
  • Surface area: ≥900 m²/g
  • CTC activity: ≥50% (indicates good capacity for medium-weight hydrocarbons)
  • Moisture resistance: low ash, hydrophobic surface preferred
  • Regeneration: thermal (steam or hot nitrogen) at 150–200°C

4. VOC Emission Control

Gas processing plants, compressor stations, and storage facilities produce VOC emissions from process vents, tank breathing losses, and fugitive sources. Activated carbon adsorption is the standard control technology when:

  • VOC concentrations are too low for thermal oxidation (below 25% LEL)
  • The VOC stream is intermittent or variable
  • Solvent recovery makes economic sense

Fixed-bed carbon adsorbers with two beds in alternating adsorption/regeneration cycles are the standard configuration. The regenerated VOCs can be recovered as liquid or routed to a flare.

Especificaciones:

  • Carbon type: coal-based pellet (3–4 mm) for low pressure drop, or granular (4×10) for higher capacity
  • CTC activity: ≥60% (higher CTC = more VOC capacity per bed volume)
  • Butane activity: ≥25% for general VOC applications
  • Working capacity: depends on specific VOC and regeneration conditions
  • Regeneration: steam at 120–150°C, or hot nitrogen

5. Biogas and Landfill Gas Upgrading

Biogas upgrading to biomethane (renewable natural gas) requires removal of H₂S, siloxanes, and VOCs before the gas enters membrane or PSA upgrading systems. Activated carbon handles all three contaminant groups, often in a multi-stage configuration:

  • Stage 1: KOH-impregnated pellet carbon for bulk H₂S removal
  • Stage 2: Virgin or specialty carbon for siloxane and VOC removal

For detailed biogas and landfill gas treatment specifications, see our sulfur removal guide.

Huamei Carbon warehouse with pallets of orange 25 kg Premium Activated Carbon bags stacked for export and close-up inset of 4mm coal-based pellet activated carbon granules for biogas and VOC treatment

Carbon Type Selection by Gas Treatment Application

Aplicación Target Carbon Form Impregnación Key Spec Bed Life
LNG mercury

guard

Hg⁰ Pellet

3–4 mm

Sulfur

(10–15%)

Hg capacity,

low pressure drop

3–10 years
Natural gas

H₂S

H₂S Pellet

3–4 mm

KOH or KI H₂S cap ≥0.15 g/g 6–18 months
Mercaptan

odor

R-SH Granular

4×10

NaOH or virgin Iodine ≥900 12–24 months
BTEX from

glycol

BTEX Granular

4×10

None CTC ≥50%,

SA ≥900

6–12 months

(regenerable)

VOC emission control Mixed VOCs Pellet

3–4 mm

None CTC ≥60%,

butane ≥25%

3–5 years

(regenerable)

Biogas H₂S H₂S + siloxanes Pellet

3–4 mm

KOH CTC ≥60%, pH 9–11 6–12 months

How to Specify Activated Carbon for Gas Treatment

When sourcing carbon for gas treatment, provide your supplier with:

  1. Gas composition — full analysis including target contaminants, moisture, CO₂, and hydrocarbon content
  2. Flow rate and pressure — Nm³/hr and operating pressure (bar/psi)
  3. Target outlet levels — what contaminant concentrations must you achieve?
  4. Operating temperature — ambient or elevated?
  5. Vessel constraints — if retrofitting existing equipment, the diameter and bed height are fixed
  6. Regeneration capability — do you have steam or hot gas available for regeneration?

Huamei Carbon produces coal-based carbón activado en pellets for gas treatment applications, including H₂S removal, mercury guard beds, VOC control, and biogas upgrading. We offer virgin, KOH, KI, NaOH, and sulfur-impregnated grades in pellet diameters from 0.9 mm to 8 mm.

📱 WhatsApp: +86 181-3792-7803
📧 Email: sale@huameicarbon.com
🌐 Website: www.huameicarbon.com

Preguntas frecuentes

What type of activated carbon is used for gas purification?

Coal-based pellet activated carbon (3–4 mm diameter) is the standard for most gas purification applications. Pellet form provides low pressure drop and uniform gas distribution in fixed-bed vessels. For mercury removal, the carbon is impregnated with sulfur. For H₂S removal, KOH or KI impregnation is standard.

Can activated carbon remove mercury from natural gas?

Yes. Sulfur-impregnated activated carbon (10–15% sulfur loading) is the standard mercury guard bed in LNG and gas processing plants. Mercury reacts with sulfur to form stable HgS trapped in the carbon pores. These beds typically last 3–10 years and achieve outlet levels below 0.01 µg/Nm³.

How does activated carbon compare to iron sponge for gas treatment?

Iron sponge is cheaper per ton but has lower H₂S capacity per volume, creates pyrophoric waste, and can't handle mercaptans or other contaminants. Activated carbon — especially impregnated grades — has higher capacity, produces non-hazardous waste, and can be specified for multi-contaminant removal. For operations above 100 Nm³/hr, activated carbon typically has lower total cost of ownership.

How long does activated carbon last in gas treatment?

It depends on the application and contaminant loading. Mercury guard beds: 3–10 years. H₂S removal (KOH-impregnated): 6–18 months. VOC adsorbers with regeneration: 3–5 years. Biogas H₂S: 6–12 months. Higher inlet concentrations and higher flow rates shorten bed life.

Is pellet or granular activated carbon better for gas treatment?

Pellet carbon is generally preferred for gas-phase applications because the uniform cylindrical shape provides more predictable pressure drop and better gas distribution than irregularly-shaped crushed granular carbon. Pellet carbon also generates less dust during loading and operation. Granular carbon is used where higher surface area per volume is needed, such as BTEX guard beds on glycol systems.

Contacto

Contact us page form
linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram